TitleProduct

High Voltage Resonant Test System

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Hubei

  • Validity to:

    Long-term effective

  • Last update:

    2020-10-13 14:45

  • Browse the number:

    454

Send an inquiries

Company Profile

Wuhan Goldhome Hipot Electrical Co., Ltd

By certification [File Integrity]

Contact:goldhomehipot2020(Mr.)  

Email:

Telephone:

Phone:

Area:Hubei

Address:Hubei

Website:http://www.hvcablehipot.com/ http://goldhomehipot2020.artelholdings.com/

PRODUCT DETAILS

High Voltage Resonant Test System:800kvA/50kV


Product description


Inductive resonant test set is one kind of resonant test set,it make the frequency as 50hz or one specific frequency, we also call it as power frequency resonant test set. It is with all the advantages of common resonant test set. In order to meet the needs of large capacity and high voltage (ultra high voltage) to test electrical equipment, the booster device using a series resonant principle, with adjustable reactor and test equipment (capacitive) or the capacitance compensation capacitor to form a resonant matching. Thus, the test power supply only takes the active component, which is only 1/Q times of the required capacity of the test, and the capacity and weight of the test equipment are greatly reduced. It is an ideal AC high voltage hipot tester.


Hot tags: power frequency resonant test set,inductive resonant test set,ac resonant test set,ac withstand voltage test set, hipot tester, high voltage test equipment manufacture 


Inductive resonant test set Feature & Function

1. Over-voltage and transmission over-voltage protection: this device to a proper wiring mode, perfect protection links and energy absorption step by step, to prevent counterattack, over-voltage and transmission over-voltage infringement. After years of field practice, it can be proved that the test set can not avoid the damage and threat to the whole set of test device and the on-site test personnel when they are flashover or breakdown. At the same time, the failure point of the tested product can be avoided, and the damage is not enlarged after flashover or breakdown.

2. Small size, light weight, easy installation and transportation, simple wiring, very suitable for on-site personnel operation.

The main function as below:

(1) Telemetry function of reactor core gap:

The device is provided with a gap sensor on the reactor, and the gap of the iron core can be directly read out on the console to guide the operation, and a gap limit switch and an indication are additionally arranged.

(2) Withstand time to automatic step-down function:

Digital timer is used for withstand timing and when reach to withstanf voltage time, the system will automatically step-down

(3) Zero turn on and zero rise:

Zero limit function, if the voltage regulator is not zero, the high voltage output button can not close, and ensure that the system is from zero to step up.

(4) Over current protection function:

The system is equipped with electromagnetic overcurrent relay, this relay anti-interference ability, quick action, to avoid test products not flow damage.

(5) Overvoltage and the flashover protection function of the tested products:

The utility model is provided with an electronic overvoltage flashover protective plate to avoid the damage of the test product not subjected to pressure and flashover, and the action is rapid.

(6) Real-time monitoring function of each test data:

The voltage, current and the voltage and current on the low voltage side can be monitored, so that the test can be understood more intuitively.


Main Technical data for 800kvA/50kV power frequency series Resonant Test System

1. Excitation transformer JLB-80kVA/4/5/6kV,  1unit

A) Rated capacity: 80kVA;

B) Input voltage: 400V, single phase;

C) Output voltage: 4/5/6kV

D) Structure: dry type;

2. Operation desk, TC-80kVA/380V,  1unit

A) Rated capacity: 80kVA;

B) Input voltage: 380V;

C) Output voltage: 0~400V;

D) Protection function: zero position, over current, over voltage and test sample flashover protection;;

3. Adjustable reactor HMCXL-200kVA/50kV,  1unit

A) Rated capacity: 200kVA

B) Rated voltage: 50kV;

C) Current rating: 4A;

D) Inductance: 25~100H

E): Quality factor Q = 40;

F) Structure: dry adjustable;

3. Fixed reactor DK--200kVA/50kV, 3units

G) Rated capacity: 200kVA

H) Rated voltage: 50kV;

I) Current rating: 4A;

J) Inductance: 25H*2, Taiwan, /35H*1

K): Quality factor Q = 40;

L) Structure: dry adjustable;

4. Capacitor voltage divider FRC-50kV 1

A) Rated voltage: 50kV;

B) Measurement accuracy: AC RMS 1.5;

C) Dielectric loss: TG = 0.5% sigma;

D) Partial pressure ratio: 1000:1, voltage ratio error: less than 1%;


Company profile










http://www.hvcablehipot.com/