TitleProduct

3 Phase Multifunction Meter

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Beijing

  • Validity to:

    Long-term effective

  • Last update:

    2023-12-26 12:12

  • Browse the number:

    226

Send an inquiries

Company Profile

KINGNEN Technology Co., Ltd.

By certification [File Integrity]

Contact:kaixianxinneng(Mr.)  

Email:

Telephone:

Phone:

Area:Beijing

Address:Beijing

Website:http://www.kingnenmeter.com/ http://kaixianxinneng.artelholdings.com/

PRODUCT DETAILS





Overview






PMC200S three-phase digital multi-function energy meter is a compact panel-mounted power measurement and control instrument, which integrates data acquisition and control functions, and replaces a variety of instruments, relays, transformers and other components through extended DI/DO, AI/AO modules to meet the needs of different application scenarios.



 








Products Description






As a panel-mounted instrument, PMC200S achieves accurate measurement of highly nonlinear loads based on the measurement of rms. Advanced grid frequency simultaneous sampling technology enables it to accurately measure a wide range of power parameters, including voltage/current, frequency, power, power factor, energy and current/voltage harmonics.



Compared with traditional energy meters, PMC200S has both data acquisition and control functions, compact size, easy to deploy and cost saving features, and can be widely used in energy management systems, substation automation, distribution network automation, community power distribution, industrial automation, power plant power systems, intelligent buildings, intelligent distribution panels, high and low voltage switchgear and other scenarios.



By using the PMC200S, you can gain insights into power load conditions, identify peak energy consumption periods, and take targeted energy-saving measures. Our product offers a 485 communication interface, allowing you to interact with other devices and smart systems, enabling more intelligent energy management.



We are committed to providing you with comprehensive and reliable energy monitoring and management solutions, helping you achieve energy-saving and emission reduction goals while improving cost-effectiveness. Choose our multifunctional meter, and you will enjoy advanced technology, convenient operation, and a durable quality guarantee.



 








Features







 










































































































































Host features



Instantaneous true RMS value



Current


each single phase and conjunction, average

Phase voltage/line voltage


each single phase and conjunction, average

Active, reactive, apparent power


each phase and the sum of three phases

Power factor


each phase and the sum of three phases

Frequency


45~65Hz

Maximum/minimum value



Max/min rms current



Max/min rms phase voltage



Max/min total active, reactive, apparent power



Max/min total power factor



Max/min frequency



Max/min THD I and THD U



Demand and peak demand value



Current per phase


current value/peak/month end peak

Total active, total reactive, total apparent power


current value/peak/month end peak

Energy



Input/output/total active energy


1 pulse output

Input/output/total reactive energy


1 pulse output

Apparent electrical energy



Compound rate of electrical energy



8 recharge periods, 4 rates can be set



Power quality



Total Harmonic Distortion Rate (THD)


current and voltage

1st-31st harmonic analysis


current and voltage

Voltage crest factor CF and current K coefficient



Event logging



100 SOE event records



Alarm system



8 configurable limit alarm channels



4 configurable logical alarm channels



Communication



RS-485 /MODBUS-RTU



Display



STN LCD display



Real-time clock



Year, month, day, minute, second



Other



Program online upgrade supported




 





























Optional features



Digital Input (DI) module (optional)



4 switching inputs



Digital Output (DO) module (optional)



2 relay outputs, which can be set by local overrun alarm or controlled remotely



Analog Input (AI)/Output (AO) module (optional)



A total of 2 channels. Optional 4-20mA DC analog input, 0-5V DC analog input, 4-20mA DC analog output




 








Specifications






 















































































































































































































































Electrical characteristics



System



Three-phase three-wire AC system, three-phase four-wire AC system;



Sample rate



128 samples per cycle



Data refresh rate



1s



Measurement accuracy



Current



±0.2%FS



Voltage



±0.2%FS



Power



0.5S



Frequency



±0.001Hz



Active energy



0.5S



Reactive energy



1.0S



DC input (AI)



0.5% FS



DC output (AO)



0.5% FS



Voltage input



Measure voltage



3*220/380V(Direct input)



3*57.7/100V (PT secondary)



Overload



1.2x/continuous



Input impedance



300KΩ



Current input



Measure current



5A (CT secondary) or 1A (CT secondary)



Overload



1.2x/continuous



Input impedance



<0.1Ω



Digital input



Operating voltage



12~24VDC



Input impedance



12KΩ



Isolation voltage



2KV



Digital output



Node type



Mechanical contacts



Node capacity



220 VAC/5A、30 VDC/5A



4-20mA DC input measurement



Measure current



4~20mA



Allowed overload capacity



1.2x/continuous



Input impedance



10Ω



Isolation voltage



2KV



0-5V DC input measurement



Measure voltage



0~5V



Allowed overload capacity



1.2x/continuous



Input impedance



12.5KΩ



Isolation voltage



2KV



4-20mA DC output



Open-circuit voltage



15VDC



Load capacity



≤600Ω



Isolation voltage



2KV



Working power supply



AC



100~240VAC/45~65Hz



DC



100~375 VDC



power consumption



< 3W



Mechanical characteristic



Weight



0.5kg



IP protection rating



Instrument panel IP52, instrument body IP30



Size



host



96 *96 * 72 mm



Host + module



96 * 96 * 120 mm



Operating temperature



display



-20~70°C



Instrument



-25~70°C



Storage temperature



instrument + display



-40~85°C



Humidity



5% ~ 90%RH, non-condensing



Electromagnetic compatibility



Electrostatic discharge



IEC 61000-4-2,Level 4



Fast transient



IEC 61000-4-4,Level 4



Surges



IEC 61000-4-5,Level 3



Magnetic fields



IEC 61000-4-8,Level 3



Electrical insulation



Insulation resistance



GB/T13729,>50MΩ



AC voltage



GB/T13729, AC 2KV 50Hz /1min



Impulse voltage



GB/T13729,5KV,1.2/50us




 








Dimensions






The size of the instrument is shown below.





 








Mounting






Embed the meter into the 90mm*90mm cutout slot and screw on the fixing buckle.





 








Application






As shown in the figure below, the instrument is in the collection layer, responsible for the measurement and collection of power data of each loop, at the same time, the instrument equipped with DI/DO, AI/AO module can realize switch status monitoring, relay output, DC voltage and current input monitoring and transmitter, can also be customized according to your demands.










Ordering guide






 






































































Model code: PMC200S-(1)-(2)-(3)-(4)-(5).



(1)Input voltage and current:



1



57.7/100V rated measurement voltage, 5A rated measurement current.



2



57.7/100V rated measurement voltage, 1A rated measurement current.



3



220/380V rated measurement voltage, 5A rated measurement current.



4



220/380V rated measurement voltage, 1A rated measurement current.



(2)Power supply:



1



Power supply: 85~264 VAC/45~65Hz, 100~300 VDC.



(3)DI:



0



No DI



4



4-way DI



(4)Optional:



0



No optional



1



Optional 1 relay output (RL1+, RL1-port).



2



Optional 2 relay outputs



(5)AI&AO:



ab



"a" is for selecting the AI/AO module for AIO1 port, and "b" is for selecting the AI/AO module for AIO2 port. The optional modules are:



0 - None



1 - 5V DC analog input measurement (AI)



2 - 420mA DC analog input measurement (AI)



3 - 4~20mA DC analog output (AO)



For example, "ab = 00" means the AI/AO module is not selected for AIO1 port, and the AI/AO module is not selected for AIO2 port. "ab = 12" means the AIO1 port is equipped with the 5V DC analog input measurement module, and the AIO2 port is equipped with the 420mA DC analog input measurement module.




 








About Us






Founded in 2014, Kingnen Co., Ltd. is a professional manufacturer of power system debugging equipment and intelligent measurement and control instruments. We specialize in independent research and development, production, and sales. We are a national high-tech enterprise and have obtained the Shenzhen Double Soft Certification. Our company is located at Building CD, Block 4, Tian'an Digital City, Shenzhen, China, occupying 1,500 square meters of office space and a 3,000 square meter factory.



 








After-Sales Service






We promise to provide excellent product quality assurance and comprehensive after-sales service support as agreed, ensuring your satisfaction. We guarantee transparent warranty terms and will strictly fulfill our contractual obligations, allowing you to enjoy long-term warranty benefits. During the agreed after-sales service period, we provide free professional services to address all your concerns. Even after the service period, we will negotiate reasonable charges with you to ensure that you continue to receive high-quality service without additional burdens.



 








FAQ






1.Are expansion modules necessary?

Input/output expansion modules are not necessary, but they allow for features such as switch status monitoring, relay outputs, DC voltage and current input monitoring, and transmitters. We can also provide customization based on your specific requirements.



 



2.How many PMC200S can be configured under the same acquisition node?

Using a Category 5e shielded twisted pair cable, you can configure up to 32 devices under the same node. If there are no repeaters, the total bus length should not exceed 1200 meters.



 





http://www.kingnenmeter.com/